Current off grid solar setup (one of them, lol). 500W of solar (used REC solar panels reclaimed from a whole house install), Victron MPPT controller, two AGM batteries 180Ah 12V and a 1000W inverter (used just for powering a pond pump, timer activated using a Shelly 1 controller). Everything else runs off 12V. #projects #diy #off grid
@ai6yr how far is the ups from the 12v batt? And what's the ups battery voltage?
@PatrickHerd Well, this is a UPS in another building 50 feet away?, and attempting to charge it using A/C off the inverter (since it is not close). The UPS systems I have do *not* like inverter power.
@ai6yr I was contemplating the insanity of a victron 12:48V dc to dc, run 48v to the ups and then use another (isolated) dc to dc at the ups to charge the batts. 50' might not be tooo silly
@ai6yr Great info, especially about the solar generator scenario.
@ai6yr who do you recommend for good inverters ? (i don't need a big one, it's just for emergencies off a small battery. my 300w that i got in a kit has whiny chihuahua fans that go off when you look at it funny, at nowhere near 100w. i'd like one that is quietish under 100w — not silent, but fans that don't sound like joe pesci)
@tati The ones built into the "solar generators" seem to be pretty good, but obviously can't be run off external batteries.
@tehfishman @ai6yr @tati
Be careful with the Ecoflow units. The Delta 3 max does not have an plug for an expansion battery while the Delta 3 does. That was an expensive lesson.
@deafboy Oooh, nice job on those breakers. I really should do that on the system I have, which is all individual fuses on the cords.
very nice. You're right about using 12V lifepo4s in series for 24V being less than ideal. If you have bluetooth BMS, you'll want to keep an eye on the cell balances in each battery. The small drift in balance between batteries can result in one of the batteries not getting enough balancing time or voltage. No big deal if you check them about once a month or so. If they start getting out of balance, just charge each battery up separately with a 12V charger.
It's no big deal for a free standing external system like this, but if you build a system in a shed or against the house, it would be good to have something like cement board as the mounting surface or add a thin layer of metal so an equipment flare-out won't catch anything else on fire.
Also, just FYI. Those battery disconnect switches are a little notorious. Mine failed after less than 6 months. thankfully as an open circuit rather than catching fire. I plan to replace it soon with a properly rated DC breaker instead.
@exador23 @deafboy @ai6yr Yeah I don't think fire codes have caught up to home battery banks yet. I get how newer tech batteries offer a lot, but think I'd much prefer AGM without real firewall & gap between batteries and house. Seldom if ever see any mention of the fire risk or mitigation considerations.
@CliffsEsport @exador23 @deafboy LFP is pretty safe, compared to LiPo. (MUCH safer).
@exador23 @deafboy @ai6yr re 2x 12v in series, these things rock https://www.victronenergy.com/batteries/battery-balancer
@PatrickHerd @exador23 @deafboy
Oooh, they have an inverter, I may have to replace the one I have in my system with this, and migrate the other one to another system. I have been very pleased with the switch of my solar charge controllers to Victron. (my attempt to use the Renogy 1000W during my last heatwave/blackout was quite a failure... could not recharge any of my solar generators, UPS units were unhappy... all of it quite unfortunate). I may have to get the GFCI version (outdoors in a shed) though.
They make quality gear, and quite compact, so the RV DIY solar community use them almost exclusively. But the home-scale DIYers usually go with other companies to avoid the "Blue Tax" as it's called. lol.
@exador23 @PatrickHerd @deafboy More expensive, but the reliability of the systems definitely is a huge plus. I'm just jaded having INFLATED an SLA battery with a cheap Chinese solar charger back when I started on this. 😬 (where it decided, it's not a 12V battery, it's a 24V battery. So much for "auto sensing!")
Yeah. You definitely want quality components. But price and even brand name isn't always the determining factor for that. Battle Born is one of the most expensive 12V battery brands out there and the had a strong reputation up until Will Prowse demonstrated they're ticking time bombs. Some of the chinese batteries on the other hand are super cheap and have been revealed to have incredibly good build quality.
But then there's product support to think about. Victron and EG4 shine through as the most dependable on all fronts. Victron is probably the best choice for premium small RV/boat installs and EG4 for larger DIY systems.
@ai6yr Ben this was best actual testing I found about it, but from 2017 and they were only testing small batteries unless I misread https://www.fire.tc.faa.gov/pdf/TC-16-17.pdf
@ai6yr btw. Finally looked closer at your battery setup.
Wires look a little small to me, though probably not horrible for 1000W at 12V (85A). Should be at least 4 awg. The wing nuts are a little concerning too. I'd add a lock washer under those at a minimum so they don't loosen under heat cycling. Also, are both home runs connected to the same battery? On a parallel battery set-up, you'll get better power sharing if you connect your chargers/inverters to the positive of the battery on one end in a parallel string and the negative from the battery on the opposite end.
And FWIW those are automotive AGMs meant for starting cars - so designed for short term large cold cranking amp discharges then charged back up and held at full. You would have gotten better performance and life from a deep cycle battery designed for slow steady discharge and charge cycles. I'm surprised it's performed OK for you for this long.
@exador23 Thanks! The smaller wires are from the MPPT and another to the 12V distribution block inside (which is.. probably not great... need a real panel in there). The larger wires go directly to the 1000W inverter, and are what were shipped with the Renogy. Noted on the lock washers. Yes, they are automotive AGMs, the choice was made as they were cheap from Costco, lol. I previously had two 6V golf cart batteries in series, and that performed AWFULLY. These are doing pretty good, considering. I have two 12V LFP batteries I purchased last year (cheap) because I thought these were going to fail, HOWEVER, using your advice I changed the Victron's charge voltages to match the specs for AGM... and suddenly these things are doing VERY well. They were not properly charging for the first part of their life!! I have checked the wires btw with the FLIR at peak current times and because the run is so short (less than a foot) no issues with heat.
Yeah. was just thinking of adding, that you have no worries as long as you check with your FLIR camera every now and then. All the concerns with wires and connections are heat related. (resistance really - which will result in voltage drops and the resulting power lost as heat generation).
@exador23 The wire is the largest size that will fit inside the Victron's opening, whatever that is.
Random comments:
Each solar panel was $50 each (yay for a secondary market on these), full output even though older. I think they were on a house only very briefly and then removed and then warehoused.
MPPT charger is SO MUCH BETTER than cheaper stuff. Victron really worth the money.
AGM batteries: probably better to go LFP nowadays, these were before LFPs dropped in price.
Renogy 1000W inverter: meh. It does NOT like a lot of my equipment. Cannot recharge a "solar generator" because they try to draw a full 1500W circuit to recharge nowadays... trips the inverter circuit. Also, similar issue with using the inverter to recharge a UPS. I need to upgrade to a larger inverter, but they are $$$$.
#solar #project #diy